RESEARCH ARTICLE INTELLIGENCE

Articles Published 14 June 2026

Analysis Of Multistorey Commercial Building Using Etabs

AUTHORS & AFFILIATIONS

Sourabh Koralli Professor, Department of Civil Engineering, Faculty of Engineering and Technology, Sharnbasva University, Kalaburagi, India.
Santosh Gobbur Student, Department of Civil Engineering, Faculty of Engineering and Technology, Sharnbasva University, Kalaburagi, India.

READER ENGAGEMENT

Article metrics

Source-labelled data
139Article / abstract viewsOJS COUNTER usage records
153PDF downloadsOJS COUNTER usage records
16Views · last 30 daysOJS COUNTER usage records
20PDF downloads · last 30 daysOJS COUNTER usage records
Readership over time

Recorded months within the last 12 months. Each bar shows recorded access events; the current month is partial.

● Article / abstract views● PDF downloads
Jun 2026
30 views
16 PDF downloads
Jul 2026
42 views
37 PDF downloads
Aug 2026
26 views
66 PDF downloads
Sep 2026
29 views
21 PDF downloads
Oct 2026
12 views
13 PDF downloads

Usage totals reflect processed OJS records and may lag recent visits. Citation sources count independently and are not combined.

Keywords:

Shear wall, Commercial building, Storey drift, Storey displacement, ETABS

Abstract

Shear walls are among the most effective structural components used in reinforced concrete (RCC) buildings to resist lateral loads caused by wind and seismic forces. Their proper placement significantly improves the stiffness, stability, and overall structural performance of high-rise buildings. This study investigates the effect of different shear wall locations on the behaviour of a G+30 multistorey commercial building using ETABS software. Four structural models were developed and analysed: a conventional frame structure without shear walls, a model with shear walls at the corners, a model with shear walls at the centre, and a model with shear walls at both the centre and corners. Linear static analysis was performed to evaluate key response parameters such as storey displacement and storey drift. The results indicate that the inclusion of shear walls considerably reduces lateral displacement and inter-storey drift compared to the conventional frame system. Among the analysed configurations, the model with shear walls placed at both the centre and corners exhibited the best structural performance, providing maximum stiffness and enhanced resistance against lateral loads. The study concludes that optimal shear wall placement is essential for improving the safety, serviceability, and seismic performance of high-rise commercial buildings.

FULL TEXT

Read the article

DOWNLOAD PAPER

Published

14-06-2026

How to Cite

Sourabh Koralli, & Santosh Gobbur. (2026). Analysis Of Multistorey Commercial Building Using Etabs. Journal of Scientific Research and Technology, 4(6), 300–322. Retrieved from https://www.jsrtjournal.com/index.php/JSRT/article/view/487

Issue

Section

Articles
SCHOLARLY DISCOVERY

Follow the research record

Check article metadata and journal source records in their original services.

Clarivate Web of ScienceWeb of ScienceESCI till 2024 · historical verification PDF ↗ Google ScholarGoogle ScholarJournal profile ↗ CrossrefCrossrefDOI records ↗ ResearchGateResearchGateJournal page ↗ ISSN International CentreISSN 2583-8660Official serial record ↗ SciSpaceSciSpaceJournal record ↗ OpenAlexOpenAlexScholarly source record ↗ ScilitScilitJournal source record ↗ Semantic ScholarSemantic ScholarTitle search ↗ Academia.eduAcademia.eduJSRT profile ↗ ROADROADISSN directory record ↗ SJIFactorSJIFactorJournal listing ↗ Cresta MetricsCresta MetricsJournal profile ↗ ZenodoZenodoISSN search ↗ OpenAIREOpenAIRE-connected recordZenodo source record ↗ International Impact Factor ServicesIIFSService reference ↗